You may be experiencing SDI input issues if:
- The Live Event/Recordings and ProVues health statuses are “CRITICAL.”
- Live or recorded output is black or displays a frozen image.
- The Dashboard Channel Preview is black or displays a frozen image.
- Recordings fail or result in black video and silent audio.
NOTE: If the Live Event/Recordings and ProVues health indexes are hidden when there’s an issue with the source, a CRITICAL status will not be triggered.
Initial Diagnostic Steps
- Check Health Status
- Navigate to the System Health page in the HyperCaster web interface
- Observe the health status for Live Event/Recordings and ProVues.
- If either or both are CRITICAL, it likely means that a stable signal is not detected.
- Test Using the Preview Channel
- On the Dashboard, locate the SDI source on the right side of the page.
- Click on the Gear icon for the SDI source.
- Select Go Live.
- Assign the SDI input to the Preview (Integrated) channel for a few minutes.
- Monitor the Preview output on the Dashboard:
- If black or frozen with 0 bps under the preview, the signal is not reaching the system properly.
- If visible and clean, the issue may be isolated to live or record configurations.
- Perform a Test Encode
- If not already recording, and if the HyperCaster is licensed for SDI encoding, click on the Dashboard tab.
- Locate the SDI source on the right side of the page.
- Click on the corresponding Gear icon.
- Select Record Now.Set a duration for a short recording (1–2 minutes).
- If the recording timecode does not advance, move to Hardware and Signal Path Checks below.
- Upon completion, review the recorded file:
- If the recording is missing from your Content tab, an SDI signal is not making it to the HyperCaster’s encoder.
- If the file is showing a black or frozen image, confirm that the expected signal is present on the SDI feed going into the HyperCaster.
- If the recording is successful, the issue may pertain to live channel configuration.
Hardware and Signal Path Checks
- Check Video Router Configuration
- Confirm that the source is routed through the video routing switcher, if present, into the correct port on the HyperCaster.
- If possible, verify the signal is present in the router via external monitor.
- Try a Different Input Source
- Replace the current SDI source with a known-good SDI feed (e.g., from a camera, decoder, or switcher).
- Re-test both Preview and Record functionalities.
- Try SDI Input Ports
- Move the SDI cable to a different input port on the HyperCaster, if available.
- If necessary, configure the new port as an input port.
- Confirm input health and re-test.
- If your HyperCaster has multiple rows of SDI ports, try a port on a different card.
- If necessary, configure the new port as an input port.
- Confirm input health and re-test.
- Swap to a Known-Good BNC Cable
- Replace the current BNC cable with one that has been tested and confirmed working and capable of supporting the resolution transmitted (see table below).
- Ensure all connectors are firmly seated.
| Cable class (75 Ω coax) | SD-SDI (270 Mb/s) | HD-SDI (1.5 Gb/s) | 3G-SDI (2.97 Gb/s) | 6G-SDI | 12G-SDI |
|---|---|---|---|---|---|
| Mini coax (≈23–26 AWG, “mini-RG59”) | 200–300 m (650–980 ft) | 50–80 m (165–260 ft) | 35–60 m (115–200 ft) | 60–100 m (200–330 ft)* | 35–70 m (115–230 ft) |
| RG59 precision 75 Ω | 300–400 m (980–1,310 ft) | 80–120 m (260–395 ft) | 60–90 m (200–295 ft) | 90–130 m (295–425 ft)* | 60–100 m (200–330 ft) |
| RG6 precision 75 Ω | 350–450 m (1,150–1,480 ft) | 110–150 m (360–495 ft) | 80–110 m (260–360 ft) | 110–150 m (360–495 ft)* | 70–110 m (230–360 ft) |
| Ultra-low-loss 75 Ω (12G-optimized) | 450–550 m (1,480–1,800 ft) | 140–160 m (460–525 ft) | 100–120 m (330–395 ft) | 130–150 m (425–495 ft) | 90–110 m (295–360 ft) |
5. Power Cycle the Source Device(s)
- Restart the SDI source device (e.g., camera, switcher) and any other devices in the signal path (e.g., converters, video routing switcher).
- Allow the device(s) to fully boot and re-establish SDI output.
- Perform another test recording.
System-Level Reset
Perform a Clean Power Down of the AIO
If the steps above fail to resolve the issues experienced by the HyperCaster:
- Shut down the HyperCaster via the web GUI or physical power button.
- Web GUI
- Navigate to the Config page
- On the left side, select Shutdown/Reboot
- Select Shutdown.
- Physical Power Button
- Press and hold the power button on the top left corner of the front panel for 3-5 seconds to trigger a graceful shutdown.
- To access the power button on B2000 HyperCasters, remove the faceplate by pulling firmly on the right side of the faceplate.
- Web GUI
- Once shut down, disconnect the HyperCaster’s power cable(s) completely.
- Wait at least 2 full minutes to ensure SDI card resets.
- Reconnect power and boot the system.
- Re-test the SDI input for signal and health.
Additional Tips
- Confirm that the BNC cable is capable of supporting an SDI signal (see above table).
- Ensure the input format matches what the AIO supports (e.g., 1080i59.94, 720p60).
- Avoid excessively-long SDI cable runs (no longer than 100 meters for HD) or poor-quality connectors.
- Ensure that there is video and audio present in the SDI signal.
- Consider using an SDI distribution amplifier (DA) to regenerate signal strength if needed.
Need Further Assistance?
If the issue persists after following these steps, please gather the following information:
- Input source to include make and model of the upstream device(s).
- Input port(s) test on the HyperCaster.
- Format of the signal (e.g., 1080i59.94).
- Results from Preview and Record tests.
Then contact TelVue Support:
- Email: support@telvue.com
- Web: https://www.telvue.com/support
Article Version History:
v1.0 – October 29, 2025