If you have a WARNING or CRITICAL health alert for your HyperCaster’s RAID:
DO NOT POWER OFF THE SYSTEM
The RAID array in B1000 and B2000 HyperCaster systems ensures data redundancy and reliability. It is vital to take immediate action if a drive fails. Fortunately, the status of the HyperCaster’s RAID is one of the health parameters queried every 5 minutes. When a RAID drive fails or has degraded, the HyperCaster health status indicator changes from OK to CRITICAL. Clicking on the health status indicator will open the System Health page.
RAID Health
If you have a CRITICAL health status for your RAID on your System Health page, click on RAID to bring you to your RAID configuration page. Any degraded arrays or failed drives will be identified as either Unconfigured(bad), Failed, or Degraded. It is not recommended to hide the RAID health status.

Responding to RAID Issues
If the RAID array is degraded:
- Do not power off the system. The HyperCaster is designed to operate while the drive is replaced.
- Notify TelVue Support with details about the system and the drive failure.
- Provide a screenshot of your HyperCaster’s RAID Disk Information page (example above).
- TelVue Support will ship a replacement drive.
- Do not attempt to install a drive that is not provided by TelVue Support.
- Confirm which drive is to be replaced before removing the bad drive. If the wrong drive is replaced, it could corrupt the entire RAID and cause complete data loss.
Replacing a Failed Drive
B1000 HyperCasters ship with 4 drives, numbered 0-3. B2000 HyperCasters ship with 8 drives, numbered 0-7. HyperCaster drives in the RAID array are hot-swappable, meaning that the system is designed to remain powered on and operating while the RAID rebuilds. Do not power off the system to swap the drive. To replace a failed drive:
- Identify the failed drive by its indicator light (usually amber or red). The failed drive will also be indicated on your HyperCaster’s RAID Disk Information page.
- Before releasing a drive sled, confirm which drive has failed. If you are not sure which drive to remove, stop and contact TelVue Support. Removing the wrong drive can cause loss of the media library.
- Release the sled lever and remove the drive from the chassis.
- Unscrew and remove the failed drive from the sled and attach the replacement drive.
- Reinsert the sled and latch it securely. Do not insert and remove the new drive multiple times.
- The RAID system will automatically detect the new drive and begin rebuilding the array.
You may monitor the rebuild process through the HyperCaster web interface. Please note that rebuild times vary depending on the size and RAID configuration. Do not remove the drives during the rebuild process.
After Replacement
Once the rebuild is complete:
- Verify the RAID status to confirm the array is healthy.
- Follow TelVue’s instructions if the failed drive needs to be returned.
- Document the replacement date and steps taken for maintenance records.
Article Version History:
- v1.0 – December 2024
- v1.1 – August 2026
- v1.2 – September 11, 2026