This article explains how to send the output of an InfoVue 2 Pro to a TelVue HyperCaster for live playout or continuity.
The recommended method for a local facility network is an MPEG transport stream over UDP or RTP. An SRT workflow is also described for installations that use an SRT-capable encoder or gateway.
Before Beginning
Confirm the following information with your network administrator and broadcast system administrator:
| Item | Value to record |
|---|---|
| InfoVue 2 Pro management IP address on eth0 | |
| HyperCaster IP address or hostname | |
| Stream method | Unicast / Multicast / SRT |
| Packetization | UDP / RTP |
| Stream port | |
| InfoVue video codec and bitrate | |
| InfoVue audio format and bitrate | |
| Expected total transport-stream bitrate | |
| HyperCaster channel or channels |
You will need administrator access to both the InfoVue local configuration interface and the HyperCaster user interface.
The InfoVue 2 Pro must have its integrated encoder connected as follows:
- Connect the HDMI output from the player (left) side of the InfoVue 2 Pro to the HDMI input on the encoder (right) side.
- Connect the InfoVue management network to eth0.
- If multicast is used, connect the multicast network to eth1 and confirm that eth0 and eth1 are on different subnets.
Do not change network, firewall, VLAN, or multicast-routing settings unless you are authorized to do so. Contact your network administrator for those changes.
Recommended Method Transport Stream Over UDP or RTP
Use this method when the InfoVue 2 Pro and HyperCaster are on the same facility network or on networks with a properly routed and approved UDP/RTP path.
Configure the HyperCaster Live Stream Feed
Create the receiving feed on the HyperCaster before enabling the InfoVue output.
- Log in to the HyperCaster user interface.
- Go to Config > Live Streams.
- Select the action menu and choose Stream.
- Select the appropriate transport-stream type:
- Unicast for a one-to-one connection from the InfoVue to the HyperCaster.
- Multicast when the network is designed to distribute the same stream to multiple receivers.
- Source Specific Multicast only when your network administrator has provided both a multicast group address and a source address.
- Enter a descriptive name, such as InfoVue 2 Pro Bulletin Board.
- Configure the transport-stream fields:
- IP Address
- For Unicast, enter the InfoVue eth0 IP address as the source address.
- For Multicast, enter the multicast group address.
- Source Address: For Source Specific Multicast only, enter the InfoVue source IP address.
- Port: Enter the unique UDP/RTP port assigned for this stream. Use a port between 1024 and 65535 and do not reuse a port already assigned to another feed.
- Max Bit Rate: Enter an accurate estimate of the total incoming transport-stream bitrate, including video, audio, and transport overhead.
- IP Address
- If live captioning is being used, configure the applicable captioning options for this feed.
- Click Save.

For a unicast feed, the HyperCaster uses the InfoVue source IP and port to identify and receive the stream. For a multicast feed, the HyperCaster joins the configured multicast group.
Configure the InfoVue 2 Pro Primary Stream
- From a computer on the same network, open a web browser and navigate to the InfoVue 2 Pro static IP address.
- Sign in to the InfoVue local configuration interface using the credentials supplied for your system. The default login credentials are admin/admin.
- On the Dashboard, confirm that the disk space, HDMI connection, InfoVue engine, and encoder health indicators are green.
- Before changing stream settings, disable both the Primary Stream and RTMP Stream if any one is enabled.
- Open the Primary Stream tab.

- Enter the settings supplied by your system or network administrator:
- Destination IP address: The HyperCaster IP address for unicast, or the approved multicast group address for multicast.
- Destination port: The same port entered in the HyperCaster feed.
- Packetization: UDP or RTP, as specified for the HyperCaster feed.
- Delivery mode: Unicast or multicast.
- Output resolution: Use a resolution supported by the HyperCaster channel and downstream plant.
- Video codec: Use the codec approved for the HyperCaster channel.
- Video bitrate: Use the approved video bitrate.
- Audio source and settings: Select the required audio source and format.
- Click Save.
- Return to the Dashboard and enable the Primary Stream.
- Confirm that the encoder remains healthy and that the HDMI input is receiving the intended InfoVue display.

For unicast and RTMP traffic, use eth0. For multicast traffic, use the approved multicast configuration on eth1 and confirm multicast routing and IGMP behavior with your network administrator.
Verify reception on the HyperCaster
- Return to Config > Live Streams on the HyperCaster.
- Confirm that the feed shows a running or receiving status.
- Verify that the received video and audio match the InfoVue output.
- Create a short test stream event on the intended channel:
- In Classic view, choose Add Stream Event.
- In Calendar view, choose Stream and select the new feed.
- Select the channel, set a short test duration, and save the event.
- Confirm the source appears on the channel output or confidence monitor.
- If the InfoVue feed will be used as channel continuity, select the approved live feed as the channel continuity source after the test has passed.
Do not make the new feed the primary continuity source until video, audio, timing, and loss-of-signal behavior have been tested.
Alternative method SRT
SRT is useful when the source and HyperCaster communicate over a WAN or another network path where packet loss and variable latency are concerns.
Important compatibility note
The current InfoVue 2 Pro installation documentation identifies UDP/RTP Primary Stream output and RTMP output as the native InfoVue 2 Pro output methods. If the InfoVue local configuration interface does not display an SRT output option, do not enter an SRT address into the Primary Stream settings.
Configure the HyperCaster SRT listener
- Log in to the HyperCaster user interface.
- Go to Config > Live Streams.
- Select the action menu and choose Stream.
- Set Type to SRT.
- Enter a descriptive name, such as InfoVue 2 Pro SRT.
- Enter a unique SRT listening port between 1024 and 65535. Do not reuse a port assigned to another service or stream.
- Click Save.
The HyperCaster acts as the SRT listener. The source-side encoder or gateway must initiate the SRT connection to the HyperCaster using the HyperCaster address and this port.
If the source is outside the local network, the external firewall must allow the selected SRT port and route it to the HyperCaster. Coordinate this change with the network administrator.
Configure the InfoVue and SRT gateway
- Configure the InfoVue 2 Pro Primary Stream as described in the transport-stream procedure above.
- Set the InfoVue destination to the SRT gateway’s receiving IP address and port, not directly to the HyperCaster SRT port.
- On the SRT gateway, configure the input to receive the InfoVue UDP/RTP transport stream.
- Configure the gateway to transmit an SRT stream to the HyperCaster:
- Mode: Caller.
- Destination address: HyperCaster address reachable from the gateway.
- Destination port: The unique SRT port created on the HyperCaster.
- Latency, encryption, passphrase, and stream ID: Use the values approved for the installation. Configure the same values on both sides when applicable.
- Start the gateway output.
- Confirm that the HyperCaster SRT feed shows a receiving or running status.
The exact field names and SRT URL format vary by encoder or gateway manufacturer. Follow that device’s documentation for caller/listener, latency, encryption, passphrase, and stream-ID settings.
Schedule and test the SRT feed
- Create a short stream event using the SRT feed.
- Select the intended channel.
- Confirm video, audio, resolution, and timing.
- Test the response to a temporary source interruption if the feed will be used for continuity or unattended operation.
- Confirm that the channel returns to its configured continuity behavior when the SRT source is lost.
Troubleshooting
| Symptom | Checks |
|---|---|
| HyperCaster feed never receives a transport stream | Confirm the InfoVue Primary Stream is enabled; verify the destination IP, source IP, port, UDP/RTP selection, firewall path, and that the HDMI input and encoder indicators are healthy. |
| Unicast feed is configured but no packets arrive | Confirm the InfoVue is sending to the HyperCaster IP address and that the HyperCaster feed’s source IP is the InfoVue eth0 address. Check routing and firewall rules. |
| Multicast feed is not received | Confirm the InfoVue is using eth1, eth0 and eth1 are on different subnets, the multicast group is correct, and the network supports IGMP and multicast routing. |
| HyperCaster receives the feed but playout fails | Compare the InfoVue codec, resolution, frame rate, audio format, video bitrate, and total multiplex rate with the HyperCaster channel requirements. |
| SRT feed remains disconnected | Confirm the gateway is acting as Caller, the HyperCaster is the Listener, the destination address and port are correct, the external firewall is forwarding the port, and any encryption or stream-ID values match. |
| Video is present but audio is missing | Confirm that the InfoVue audio source is selected, the encoder is receiving audio, and the audio format is supported by the HyperCaster channel. |
| Stream stops during normal operation | Review network loss, firewall timeouts, source health, gateway logs, and the HyperCaster loss-of-signal setting. Do not change loss-of-signal behavior without understanding its effect on scheduled events and continuity. |
Information to provide TelVue Support
If assistance is required, provide:
- Organization name and affected channel.
- InfoVue model, serial number, software version, and IP address.
- HyperCaster model, software version, and IP address.
- Stream type: Unicast, Multicast, Source Specific Multicast, or SRT.
- Packetization: UDP or RTP, when applicable.
- Source and destination IP addresses.
- Port number and total expected bitrate.
- Video codec, resolution, frame rate, video bitrate, and audio format.
- Exact time the problem occurred, including the local time zone.
- Screenshots of the InfoVue Dashboard, Primary Stream settings, and HyperCaster Live Streams feed.
- Any gateway or encoder logs used in an SRT workflow.
Do not include passwords, SRT passphrases, stream keys, or other secrets in screenshots or support tickets.
Related TelVue documentation
- InfoVue 2 Pro and InfoVue 2 Standard Self-Installation Instructions
- Feed Setup
- Set Up an SRT Stream in a HyperCaster
- How do I set InfoVue as Continuity on the HyperCaster?
Article Version History